Portable Odor Gas Monitor from China Suppliers and Factory for Real-Time Environmental Odor Detection
Video Demonstration
Product Features
1. Intuitive Data Visualization & Flexibility
Displays real-time odor measurement results, including a 30-second real-time historical curve and 30-day historical data trend graphs for intuitive trend analysis.
Supports switching between real-time and minute-by-minute data views. For characteristic pollutants, it offers instant unit conversion between PPM and mg/m³. Over-standard factors trigger color-coded alerts, enabling rapid problem response.
2. Reliable Sampling System & Versatility
Adopts a negative pressure suction gas path design: Sample gas bypasses the pump to avoid secondary pollution. A front-end dynamic heating module prevents condensation during sampling, meeting requirements across diverse regional environments.
Equipped with standard quick-change connectors for navigation-based air intake/exhaust (made of SUS316 material), compatible with both vehicle-mounted and manual navigation modes.
3. Flexible Power Supply & Durability
Includes a 3-meter cigarette lighter plug cable for daily vehicle-mounted navigation use.
Built-in lithium battery provides up to 4 hours of continuous power, ensuring reliability during off-grid fieldwork.
High-strength engineering plastic shell with a pull rod, mute casters, and safety lock—designed for portability and durability in harsh environments.
4. Intelligent Data & Lifecycle Management
Automatically stores up to 365 days of data; data remains intact even when offline.
Integrated lifecycle management system: Estimates sensor lifespan based on performance and usage, allows setting lifespan alarm thresholds, and notifies users of replacement/maintenance in advance—reducing downtime from faults.
Alarm log query and export functionality: Enables users to search and export alarm records by time, simplifying post-fault troubleshooting.
5. GPS-Enhanced Location Awareness
Built-in high-precision GPS positioning module realizes seamless association of monitoring data with geographic information, supporting accurate traceability of odor sources and regional pollution mapping.
Product Specifications
| Model No. | TY-ODOR-302 |
| Sampling flow | 1500±500ml/min |
| Working temperature and humidity | -20-55℃; 10%~95%RH (no condensation) |
| Measurement response time | ≤60s |
| Power supply | 220V AC, 50Hz, 60W; Car cigarette lighter; Built-in lithium battery |
| Measure preheating time | 300s |
| Shell | made of high-strength engineering plastic, equipped with pull rod, mute caster and safety lock |
| Odor concentration | Range: 0-1000 (OU) Repeatability: ≤±3% Resolution: 1 (OU) |
| TVOC | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Ammonia | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Trimethylamine | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Hydrogen sulfide | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Methyl mercaptan | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Methyl sulfide | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Dimethyl disulfide | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Methyl sulfide | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Carbon disulfide | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
| Styrene | Range: 0-100ppm Repeatability: ≤±3% Resolution: 0.01ppm |
Application Scenarios
Government & Research: Environmental malodorous pollution monitoring and data analysis for policy-making and research.
Polluting Enterprises: Odor emission monitoring and pollution control to ensure compliance with environmental standards.
Industrial Sites: Tracing and monitoring industrial odor sources to guide deodorization process optimization.
Emergency Response: Rapid odor gas monitoring for government departments during environmental emergencies.
Frequently Asked Questions (FAQ)
What is the model number of this Odor Gas Monitor?
The model number is TY-ODOR-302.
What gases and pollutants can the TY-ODOR-302 detect?
It detects Odor concentration (OU), TVOC, Ammonia, Trimethylamine, Hydrogen sulfide, Methyl mercaptan, Methyl sulfide, Dimethyl disulfide, Carbon disulfide, and Styrene.
What are the power options for this device?
The system can be powered by 220V AC (50Hz), a car cigarette lighter, or its built-in lithium battery which supports up to 4 hours of continuous off-grid operation.
How does the sampling system prevent secondary pollution?
It utilizes a negative pressure suction gas path design where the sample gas bypasses the pump, ensuring no secondary pollution occurs during the process.
Does the system support GPS positioning?
Yes, it features a built-in high-precision GPS positioning module that links monitoring data directly with geographic coordinates for trace mapping.
How much historical data can the system store?
The system can store up to 365 days of data automatically, ensuring information remains safe even when offline.